4 – Managing Switches
Displaying Switch Information
4-10 59097-02 B
S
Zoning Default Visibility Zoning visibility status. Permits (All) or prevents (None)
communication between attached devices in the absence
of an active zone set.
Temperature Internal switch temperature °C
Security Auto Save N/A - does not apply to this switch
Security Fabric Binding
Enable
N/A - does not apply to this switch
Fan 1 Status The status of Fan 1 (SANbox 5602 only)
Fan 2 Status The status of Fan 2 (SANbox 5602 only)
Power Supply 1 Status Power supply 1 status
Power Supply 2 Status Power supply 2 status (SANbox 5602 only)
Beacon Status Beacon status. Switch LEDs are blinking (On) or not (off).
Broadcast Support Broadcast support status. Broadcast support is enabled or
disabled (default).
In-band Enabled In-band management status. Permits (True) or prevents
(False) a switch from being managed over an ISL.
Temperature Failure Port
Shutdown
Non-configurable (always enabled for this switch). All
ports are downed when the switch temperature exceeds
the Failure Temperature.
Warning Temperature Non-configurable temperature threshold (65° Celsius)
above which a warning condition alarm is generated.
Failure Temperature Non-configurable temperature threshold (70° Celsius)
above which a failure condition alarm is generated.
NTP Client Enabled Enabled or disabled. Allows for switches to synchronize
their time a centralized server.
NTP Server Address The IP address of the centralized NTP server. Ethernet
connection to NTP server is required.
FDMI HBA Entry Limit Maximum number of HBAs that can be registered with a
switch.
Table 4-2. Switch Data Window Entries (Continued)